Products
The IPC 704 signal conditioner converts the charge- based signal from a piezoelectric transducer into a current or a voltage signal.
Brand :
VMPart number :
IPC704 244-704-000-022Description :
Signal ConditionerOrigin :
SwitzerlandCondition :
NewDimension :
79.4 mm x 54 mm x 36.5 mmWeight :
170 gPayment :
Bank Transfer
IPC704 244-704-000-022 Signal Conditioner
Functional Description
The IPC 704 signal conditioner converts the chargebased signal coming from a piezoelectric transducer
into a current or a voltage signal. This current or voltage signal is transmitted to the processing electronics
via any standard 2-wire or 3-wire transmission cable. This method is advantageous as it avoids having to use
expensive low-noise cables that are necessary to transmit charge signals.
The current modulation technique allows a transmission distance of over 1000 m. A GSI galvanic separation
unit is required for this configuration.
Features
• For CA... type piezoelectric accelerometers and CP... type dynamic pressure transducers
• Configurable high-pass and low-pass filters
• Frequency range : 0.5 Hz to 20 kHz
• Optional integrator
• Optional 2-wire current or 3-wire voltage transmission
• Available in standard and Exi versions
Technical Specifications
Manufacturer | VM |
Part Number | IPC704 |
Ordering Information | 244-704-000-022 |
Product Catalog | Vibration Monitoring |
Description | Signal Conditioner |
Voltage | 24 Vdc |
Current | 25 mA |
Dimensions | 79.4 mm x 54 mm x 36.5 mm |
Weight | 170 g |